Uğur, Öykü Deniz (2024) Predictions and of the time required for a magnet drop inside a copper tube to fall for eight copper tubes with different diameters. Other thesis, TED Ankara Koleji.
| ![[img]](http://tedprints.tedankara.k12.tr/style/images/fileicons/text.png) | Text (pdf) Physics EEÖyküDenizUgur.pdf - Other Available under License Creative Commons Attribution Non-commercial. Download (744kB) | 
Abstract
The aim of this investigation is to answer the question “How does the inner diameter of a copper tube affect the falling time of a magnet that dropped and freefalling through in it?” In this experiment, falling times of 4-millimeter diameter neodymium magnet falling through copper tubes with 5-6-7-8-9-10-11-12mm inner diameter, 25cm length are measured to evaluate the relationship of emf and the distance.
| Item Type: | Thesis (Other) | 
|---|---|
| Uncontrolled Keywords: | Electromagnetism, electromagnetic induction | 
| Subjects: | Q Science > QC Physics | 
| Depositing User: | Kamil Çömlekçi | 
| Date Deposited: | 08 Oct 2024 12:26 | 
| Last Modified: | 08 Oct 2024 12:26 | 
| URI: | http://tedprints.tedankara.k12.tr/id/eprint/1309 | 
Actions (login required)
|  | View Item | 
 
        